Name
Param-
eter
Num-
Display
ber
Magnet posi-
tion offset
F1-22
Mag Theta
Comp
Encoder copy
selection
F1-25
Enc Copy Sel
Encoder copy
write permis-
sion selection
F1-26
Write Allow-
able
*1. Can be set only if HIPEFACE
5
28
5-
Description
Sets the Offset between the rotor
magnet and encoder zero position.
Used to memorize encoder and
motor data in the encoder memory
(for Hiperface and EnDat encod-
ers)
0: Normal operation
1: WRITE (Inverter to encoder)
2: COPY (Encoder to inverter)
3: VERIFY
Sets wether saving parameters in
the encoder is permitted or not.
0: Write prohibited
1: Write permitted
y
is selected as encoder type.
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 to 360
60 °
No
-
0 to 3
0
No
-
0 or 1
0
No
-
Control Methods
MEMO-
Closed
Open
Closed
BUS
Loop
Loop
Loop
Register
Vector
Vector
Vector
(PM)
-
-
A
3B1H
-
-
A
3B4H
-
-
A
3B5H
Page
6-73
6-75
6-75

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents