Name
Para-
meter
Num-
Display
ber
Adjust the strength of the zero-
servo lock.
Zero-servo gain
When Closed Loop Vector control
is selected, a position control loop
S1-20
is created at start and stop. Increas-
ing the zero-servo gain increases
Zero Servo
the strength of the lock. Increasing
Gain
it too much can cause oscillation.
Sets the bandwidth of the Zero
Servo completion output.
Zero-servo
Enabled when the "zero-servo
completion
completion (end)" is set for a
width
multi-function output. The zero-
servo completion signal is ON
S1-21
when the current position is within
the range (the zero-servo position +
zero-servo completion width.)
Zero Servo
Set S1-21 to 4 times of the allow-
Count
able displacement pulse amount at
the PG.
Starting torque
Sets the increase time for the ana-
compensation
log input torque compensation sig-
S1-22
increase time
nal. Sets the time the torque
reference needs to reach 300%
Torque incr T
torque reference.
Torque com-
pensation gain
Sets the torque compensation gain
during lowering
S1-23
at lowering when the torque com-
pensation at start function is used.
TorqComp-
gain@low
Torque com-
pensation bias
Sets the torque compensation bias
during raising
S1-24
at raising when the torque compen-
sation at start function is used.
TorqComp-
Bias@ri
Torque com-
pensation bias
Sets the torque compensation bias
during lowering
S1-25
at lowering when the torque com-
pensation at start function is used.
TorqComp-
Bias@red
Hold speed reference when the
Dwell speed
load is heavy.The frequency refer-
reference
ence follows the C1-07 accelera-
S1-26
tion 4 setting time.
Acceleration time will be changed
DWELL speed
when the motor speed exceeds the
C1-11 setting frequency.
Sets the door zone speed level.
Door zone
If the motor speed (in CLV and
speed level
OLV) or the output frequency (in
V/f control) falls below S1-27 and
S1-27
a multifunction output is set for the
"Door zone" signal
Door Zone
(H2-
Level
closed.
SE1 detection
Sets how a SE1 fault is reset.
Selection
0: Manual Reset
S1-28
1: Automatic reset at stop
SE1 Selection
2: No SE1 detection
Setting
Description
Range
0 to 100
0 to
16383
0
to
5000
0.500
to
10.000
-200.0
to
+200.0
-200.0
to
+200.0
0.0
to
120.0
0.0
to
120.0
=42), this output will be
0 to 2
Control Methods
Change
Factory
during
Open
Setting
Opera-
V/f
Loop
tion
Vector
5
No
-
-
10
No
-
-
500ms
No
-
-
1.000
No
-
-
0.0%
No
-
-
0.0%
No
-
-
0.0Hz
No
-
-
0.0Hz
No
A
A
0
No
A
A
MEMO-
Closed
Closed
BUS
Page
Loop
Loop
Register
Vector
Vector
(PM)
A
A
693H
6-13
A
A
694H
6-13
A
A
695H
6-13
A
A
696H
6-13
A
A
697H
6-13
A
A
698H
6-13
A
A
699H
6-21
A
A
69AH
6-58
A
A
69BH
6-53
5
49
5-