Note: 1. When changing the display with the Increment / Decrement keys, the next display after the one for the last parameter number will be the one for the
first parameter number and vice versa. For example, the next display after the one for U1-01 will be U1-40. This is indicated in the figures by the let-
ters A and B and the numbers 1 to 6.
2. The display for the first monitor parameter (frequency reference) will be displayed when power is turned ON. The monitor item displayed at startup
can be set in o1-02 (Monitor Selection after Power Up).Operation cannot be started from the mode selection display.

Quick Programming Mode

In quick programming mode, the basic parameters required for Inverter trial operation can be monitored and
set.
The parameters can be changed from the setting displays. Use the Increment, Decrement, and Shift/RESET
keys to change the frequency. The parameter will be written and the monitor display will be returned to when
the DATA/ENTER key is pressed after changing the setting.
Refer to
Chapter 5 User Parameters
Example Operations
Example key operations in quick programming mode are shown in the following figure.
Mode Selection Display
MENU
-DRIVE-
** Main Menu **
Operation
MENU
-QUICK-
** Main Menu **
Quick Setting
MENU
-ADV-
** Main Menu **
Programming
MENU
-VERIFY-
** Main Menu **
Modified Consts
MENU
-A.TUNE-
** Main Menu **
Auto-Tuning
for details on the parameters displayed in quick programming mode.
Monitor Display
A
B
-QUICK-
Control Method
A1-02=2
Open Loop Vector
ESC
-QUICK-
Reference Source
b1-01=1
Terminals
-QUICK-
Run Source
b1-02=1
Terminals
-QUICK-
Terminal AM Gain
H4-05 =
50%
(0.0 ~ 1000.0)
50.0%
-QUICK-
MOL Fault Select
L1-01=1
Std Fan Cooled
-QUICK-
StallP Decel Sel
L3-04=1
Enabled
A
B
Fig 3.5 Operations in Quick Programming Mode
*2*
ESC
*1*
ESC
*1*
ESC
ESC
*1*
ESC
*1*
ESC
Setting Display
-QUICK-
Control Method
A1-02=
2
*2*
Open Loop Vector
-QUICK-
Reference Source
b1-01=
1
*1*
Terminals
-QUICK-
Run Source
b1-02=
1
*1*
Terminals
-QUICK-
Terminal AM Gain
H4-05 = 0050.0%
(0.0 ~ 1000.0)
50.0%
-QUICK-
MOL Fault Select
L1-01=
1
*1*
Std Fan Cooled
-QUICK-
StallP Decel Sel
L3-04=
1
*1*
Enabled
3
7
3-