Omron VARISPEED L7 Manual page 133

Hide thumbs Also See for VARISPEED L7:
Table of Contents

Advertisement

Digital Operator: o2
Name
Param-
eter
Num-
Display
ber
LOCAL/
REMOTE key
enable/disable
o2-01
Local/Remote
Key
STOP key during
control circuit ter-
minal operation
o2-02
Oper Stop Key
User parameter
initial value
o2-03
5
User Defaults
kVA selection
o2-04
Inverter Model #
Frequency refer-
ence setting
method selection
o2-05
Operator M.O.P.
Operation selec-
tion when digital
operator is dis-
connected
o2-06
Oper
Detection
Cumulative oper-
ation time setting
o2-07
Elapsed Time Set
Cumulative oper-
ation time selec-
tion
o2-08
Elapsed Time
Run
46
5-
Description
Enables/Disables the Digital
Operator Local/Remote key
0: Disabled
1: Enabled (Switches between
the Digital Operator and the
parameter settings
b1-01, b1-02.)
Enables/Disables the Stop key in
the run mode.
0: Disabled (When the run com-
mand is issued from an exter-
nal terminal, the Stop key is
disabled.)
1: Enabled (Effective even dur-
ing run.)
Clears or stores user initial val-
ues.
0: Stores/not set
1: Begins storing (Records the
set parameters as user initial
values.)
2: All clear (Clears all recorded
user initial values)
When the set parameters are
recorded as user initial values,
1110 will be set in A1-03.
Do not set unless after replacing
the control board. (Refer to
page
5-61
for the setting values).
Sets whether the ENTER key is
needed for a frequency refer-
ence change or not when the
Digital Operator is selected as
frequency reference source.
0: Enter key needed
1: Enter key not needed
If "1" is selected, a frequency
reference change is accepted
without the need of pressing the
Enter key.
Sets the operation when the Dig-
ital Operator/LED Monitor is
disconnected.
0: Operation continues even if
the Digital Operator/LED
Monitor is disconnected.
1: OPR is detected at Digital
Operator/LED Monitor dis-
connection. Inverter output is
switched off, and the fault con-
tact is operated.
Sets the cumulative operation
time in hour units.
0: Accumulated inverter power
on time.
1: Accumulated inverter run
time.
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 or 1
0
No
A
0 or 1
0
No
A
0 to 2
0
No
A
0 to FF
0
No
A
0 or 1
0
No
A
0 or 1
0
No
A
0 to
0 hr.
No
A
65535
0 or 1
1
No
A
Control Methods
MEMO-
Closed
Open
Closed
BUS
Loop
Loop
Loop
Register
Vector
Vector
Vector
(PM)
A
A
A
505H
A
A
A
506H
A
A
A
507H
A
A
A
508H
A
A
A
509H
A
A
A
50AH
A
A
A
50BH
A
A
A
50CH
Page
6-65
6-65
6-65
6-65
6-66
6-66
6-66
6-66