Structure Of Cc-Link Ie Tsn Class B/A Devices (Cc-Link Ie Tsn Protocol Version 1.0 Only) And Ethernet; Devices - Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual

Motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

4.4
Structure of CC-Link IE TSN Class B/A Devices
(CC-Link IE TSN Protocol version 1.0 Only) and
Ethernet Devices
The following diagram shows the system configuration under the conditions below:
• "Mixture of CC-Link IE TSN Class B/A or CC-Link IE TSN Class A Only" set for "Connection Device Information" under
"Basic Settings" in the engineering tool
• When the firmware version of the master station is "1.001" or earlier or there are only CC-Link IE TSN-compatible devices
with the CC-Link IE TSN Protocol version 1.0
For the maximum number of connectable stations when "Connection Device Information" under "Basic Settings" of the master
station is set to "Mixture of CC-Link IE TSN Class B/A or CC-Link IE TSN Class A Only", check the following.
Page 20 Performance Specifications of CC-Link IE TSN
No.0
No.1
Class B (1 Gbps)
Class B (1 Gbps)
No.0: Master station
No.1, No.2, No.3, and No.4: Remote station
(1) and (2): Ethernet device
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
The availability of connection of network configuration devices varies depending on the communication mode and
communication speed.
• Unicast mode
Page 78 When the communication speed for the master station is set to 1 Gbps
Page 78 When the communication speed for the master station is set to 100 Mbps
The following terms are used to describe the terms in the tables referenced.
(1)
(2)
No.0
No.1
4.4 Structure of CC-Link IE TSN Class B/A Devices (CC-Link IE TSN Protocol version 1.0 Only) and Ethernet Devices
No.2
No.3
Class B (1 Gbps)
Class B (1 Gbps)
(1)
(2)
No.2
No.3
(1)
(1 Gbps)
General-purpose
switching hub
(2)
(100 Mbps)
No.4
Class A (100 Mbps)
No.0: Master station
No.1 and No.2: Remote station
(1) Device on the master station side (The
master station or a device near the master
station)
(2) Device on the end side (A device far from the
master station)
4 SYSTEM CONFIGURATION