*1 The sum of the Motion modules and a single FX5-CCLGN-MS (master station).
*2 The maximum number of points for all link devices may not be used simultaneously depending on the number of device stations, or the
number of points and assignments of the link devices that are set in the "Network Configuration Settings" of the "Basic Settings".
*3 This setting can be used for the firmware version "1.002" or later.
*4 Even for a firmware version "1.002" or later of the Motion module, when the CC-Link IE TSN Protocol version of the remote station is
1.0, the Motion module may operate with the CC-Link IE TSN Protocol version 1.0.
*5 Including the master station.
*6 When connecting multiple master stations, such as the FX5-40/80SSC-G and the FX5-CCLGN-MS, which use device station
parameters for the CPU module, the total number of slave modules must be less than or equal to the number of device station
parameter files that can be saved in the CPU module. For details on the number of device station parameter files that can be saved in
the CPU module, refer to the following.
 MELSEC iQ-F FX5 User's Manual (Application)
*7 To connect the Motion module to the FX5UC CPU module, the FX5-CNV-IFC and FX5-C1PS-5V are required.
2.2

Performance Specifications of Ethernet

The following table lists the performance specifications of Ethernet for the Motion module.
Item
Data transmission speed
Communication mode
Interface
Maximum frame size
Jumbo frame
Maximum segment length
Number of cascade connections
IP version
Number of simultaneous open
Connection with MELSOFT products
connections (maximum number
Connection to SLMP-compatible
of connections)
devices
*1 This setting can be used for the firmware version "1.002" or later.
*2 For maximum segment length (length between switching hubs), consult the manufacturer of the switching hub used.
*3 Consult the manufacturer of the switching hub used.
*4 In the case of one connection per device, up to eight devices can be connected.
The operation of commercial devices used for the following applications is not guaranteed. Check the
operation before using the module.
• Internet (general public line) (Internet-access service offered by an Internet service provider or a
telecommunications carrier)
• Firewall device(s)
• Broadband router(s)
• Wireless LAN
Description
• 1 Gbps
*1
• 100 Mbps
1000BASE-T
*1
100BASE-TX
RJ45 connector (Auto MDI/MDI-X)
1518 bytes
Not available
100m (distance between a switching hub and a station)
*3
Compatible with IPv4
*4
8 connections
*4
8 connections
2.2 Performance Specifications of Ethernet
Full-duplex
Full-duplex
*2