Details of buffer memory addresses

Module information area
■Latest error code (Un\G62913)
The error code for the latest error that occurred in the Motion module is stored. (0 is stored in normal condition.)
For details on error codes, refer to the following.
Page 146 List of Error Codes
■Unique code (Un\G62914)
The unique code (6988H) of the Motion module is stored.
(The same value is also stored in "[Md.59] Module information".)
For details, refer to "Monitor Data" in the following manual.
MELSEC iQ-F FX5 Motion Module/Simple Motion Module User's Manual (Application)
• Unique code of the FX5-40SSC-G: 6959H
• Unique code of the FX5-80SSC-G: 695AH
■Firmware version (Un\G62915)
The firmware version of the Motion module is stored.
(The same value is also stored in "[Md.130] F/W version".)
For details, refer to "Monitor Data" in the following manual.
MELSEC iQ-F FX5 Motion Module/Simple Motion Module User's Manual (Application)
Ex.
When the firmware version of the Motion module is "1.000": K1000
■Input signal (Un\G62918 to Un\G62919)
This signal is used to check the status of the Motion module.
Address
Bit
Un\G62918
b0
b1
b3
b15
■MIB information device version (Un\G62932)
The MIB information device version of the Motion module is stored.
• 1: Ver.1.001 or earlier
• 2: Ver.1.002
■MIB information firmware version (Un\G62933)
The MIB information firmware version of the Motion module is stored.
• 1: Ver.1.001 or earlier
• 2: Ver.1.002
■MIB information hardware version (Un\G62934)
The MIB information hardware version of the Motion module is stored.
• 1: Ver.1.001 or later
Signal name
Module failure
Own station data link status
Data link status of another station
Module READY
Description
• Off: Module normal
• On: Module failure
• Off: Data link stop
• On: Data link in progress
Shows the data link status of the own station in the
same way as 'Data link error status of own station'
(SB0049). However, the ON/OFF status is
reversed between this bit and 'Data link error
status of own station' (SB0049).
• Off: All stations normal
• On: Faulty station exists
The specifications are the same as the
specifications for 'Data link error status of each
station' (SB00B0).
• Off: Module not in operation
• On: Available for module operation
When b0 of Un\G62918 turns on, this bit turns off.