Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 192

Motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

No.
Name
SB006A
PORT1 link-down status of own station
SB0074
Reserved station specification status
SB0075
Error invalid station setting status
SB0077
Parameter reception status
SB007B
Input data status of data link faulty station
SB007D
Hold/clear status setting for CPU STOP
SB007E
Type of IP Address
SB007F
IP address setting status
SB00B0
Data link error status of each station
SB00B1
Data link error status of master station
SB00C0
Reserved station setting status
SB00D0
Error invalid station setting current status
APPX
190
Appendix 2 List of Link Special Relay (SB)
Description
Stores the link-down status of the own station P1 side.
Off: Link-up
On: Link-down
The time until link-up starts after power-on or Ethernet cable connection may vary. Normally link-
up takes several seconds. Depending on device status on the line, link-up processing is
repeated and may increase the time.
(Also used in the CLPA conformance test.)
(Updated even if set as an error invalid station.)
(Updated even if set as a reserved station.)
Stores the status of reserved station specification by parameter. The station number of the
station set as a reserved station can be checked with 'Reserved station setting status' (SW00C0
to SW00C7).
Off: Not specified
On: Specified
Stores the status of error invalid station setting by parameter. The station number of the station
set as an error invalid station can be checked with 'Error invalid station setting status' (SW00D0
to SW00D7).
Off: Not specified
On: Specified
Stores the status of parameter reception from the master station.
Off: Reception complete
On: Reception not completed
Stores the setting status of "Data link faulty station setting" of the own station.
Off: Clear
On: Hold
Stores the setting status of "Output Hold/Clear Setting during CPU STOP" of the own station.
Off: Hold
On: Clear
Stores the type of IP address.
OFF: IPv4
ON: IPv6
Stores the status of the IP address setting by parameter.
Off: No setting
On: Set
For local stations, this relay stores the acceptance status of the IP address from the master
station.
Stores the data link status of each station.
Off: All stations normal
On: Faulty station exists
When this relay is turned on, the status of each station can be checked with 'Data link status of
each station' (SW00B0 to SW00B7).
Depending on the link refresh timing, the update of 'Data link status of each station' (SW00B0 to
SW00B7) may be offset by one sequence scan.
Since a local station cannot obtain the station information of the CC-Link IE TSN Class A remote
station when communicating in multicast mode, "0: Data link normally operating station" is
reflected to the CC-Link IE TSN Class A remote station.
(Conditions)
Reserved stations and stations that surpass the maximum station number are ignored.
Stores the data link status of the master station.
Off: Normal
On: Error
Stores whether a reserved station is set.
Off: No setting
On: Set
When this relay is turned on, the status of each station can be checked with 'Reserved station
setting status' (SW00C0 to SW00C7).
Depending on the refresh timing, the update of 'Reserved station setting status' (SW00C0 to
SW00C7) may be offset by one sequence scan.
Set whether an error invalid station is set.
Off: No setting
On: Set
When this relay is turned on, the status of each station can be checked with 'Error invalid station
setting status' (SW00D0 to SW00D7).
Depending on the refresh timing, the update of 'Error invalid station setting status' (SW00D0 to
SW00D7) may be offset by one sequence scan.