Mitsubishi Electric MELSEC iQ-F FX5 Series User Manual page 152

Motion module
Hide thumbs Also See for MELSEC iQ-F FX5 Series:
Table of Contents

Advertisement

Error
Error definition and causes
code
300BH
The Announce frame send cycle
parameter error was detected.
300CH
A propagation delay send cycle parameter
error was detected.
300DH
The Sync frame send cycle parameter
error was detected.
300EH
The set values of the master station and
local station do not match.
300FH
Multiple master stations were detected in
the network.
3010H
The value set in "Communication Period
Interval Setting" in "Communication Period
Setting" under "Basic Settings" of the
master station is smaller than the
communication cycle interval calculated by
the number of stations and points of device
stations that was set in "Network
Configuration Settings" under "Basic
Settings".
3011H
The value set in "Cyclic transmission time"
in "Communication Period Setting" under
"Basic Settings" of the master station is
smaller than the cyclic transmission time
calculated by the number of stations and
points of device stations set in "Network
Configuration Settings" under "Basic
Settings".
3012H
System error
3013H
The value set in "Transient Transmission
Time" in "Communication Period Setting"
under "Basic Settings" of the master
station is smaller than the transient
transmission time calculated using the
number of device stations and the points of
device stations set in "Network
Configuration Settings" under "Basic
Settings".
3014H
System error
3015H
System error
3016H
System error
3017H
System error
3018H
System error
8 TROUBLESHOOTING
150
8.5 List of Error Codes
Action
Check the Announce frame send cycle parameter setting value of
the device operating as the grandmaster. When the Motion module
is operating as the grandmaster, reset the CPU module, and run it
again. If the same error occurs again even after taking the above
measure, the possible cause is a hardware failure of the module.
Please consult your local Mitsubishi representative.
Check the propagation delay send cycle parameter setting value of
the device operating as the grandmaster. When the Motion module
is operating as the grandmaster, reset the CPU module, and run it
again. If the same error occurs again even after taking the above
measure, the possible cause is a hardware failure of the module.
Please consult your local Mitsubishi representative.
Check the Sync frame send cycle parameter setting value of the
device operating as the grandmaster. When the Motion module is
operating as the grandmaster, reset the CPU module, and run it
again. If the same error occurs again even after taking the above
measure, the possible cause is a hardware failure of the module.
Please consult your local Mitsubishi representative.
Set the same parameter setting values for "Network No." and
"Station No." of the local station to the setting values of the master
station.
• Connect only one master station on the same network.
• After taking the above action, power off and on or reset all
stations where the error was detected.
Set the value of "Communication Period Interval Setting" as a value
equal to or larger than the value in the detailed information
displayed in "Module Diagnostics" using "Communication Period
Setting" under "Basic Settings" of the master station.
Set the value of "Cyclic Transmission Time" as a value equal to or
larger than the value in the detailed information displayed in
"Module Diagnostics" using "Communication Period Setting" under
"Basic Settings" of the master station.
Please consult your local Mitsubishi representative.
Set "Communication Period Interval Setting" and "Cyclic
Transmission Time" so that the value of "Transient Transmission
Time" in "Communication Period Setting" under "Basic Settings" of
the master station is equal to or larger than the value shown in the
detailed information displayed in "Module Diagnostics".
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Detailed information 1
Detailed information 2
■Parameter information
• Parameter type
• Intelligent module No.
• Parameter No.
• Network No.
• Station No.
■
■Parameter information
• Parameter type
• Intelligent module No.
• Parameter No.
• Network No.
• Station No.
■Overlapped type information
• 5: Master station duplication
■
■Communication Period
Interval Information
• Communication Period
Interval (Calculation value:
s)
■
■Communication Period
Interval Information
• Cyclic Transmission Time
(Calculation value: s)
■
■Communication Period
Interval Information
• Transient Transmission
Time (Calculation value: s)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-40ssc-gMelsec iq-f fx5-80ssc-g

Table of Contents