Error
Error definition and causes
code
D257H
The request type of the REQ instruction is
incorrect.
D258H
The control station does not exist when the
dedicated instruction was executed to the
specified control station or current control
station.
D25AH
The dedicated instruction was executed
specifying the channel in use.
D25BH
The dedicated instruction was executed
specifying the channel in use.
D25DH
The transient data is incorrect.
D25FH
System error
D260H
System error
D262H
System error
to
D26CH
D26FH
System error
to
D272H
D273H
The request data size of transient
transmission is incorrect.
D275H
Other dedicated instructions are in
execution, and the executed instruction
cannot be processed.
D27AH
System error
to
D27CH
D27FH
System error
D2C0H
System error
to
D2D1H
D2D2H
The IP address/port number of the target
station is incorrect.
D2D3H
Send processing of the transient
transmission has failed.
D602H
Parameter error
D605H
Parameter error
D60BH
System error
to
D622H
D625H
System error
Action
• Correct the request type in the request data, and retry the
operation.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
• Correct the target station number in the control data, and retry
the operation.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
• Retry the operation after a while.
• Change the channels used by own station or the target station's
channel in the control data.
• Execute the RECV instruction at the external device, and then
execute the SEND instruction.
Change the channels used by own station or the target station's
channel in the control data.
• Correct the transient data at the transient request source, and
retry the operation.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
• Correct the request command at the transient request source,
and retry the operation.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
• Other dedicated instructions are in execution. Execute again
after a while.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
• Execute again after correcting the port number of the target
station in the setting data.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
• Check the network status using the CC-Link IE TSN/CC-Link IE
Field diagnostics of the engineering tool, and take action.
• When the own station, target station, or relay station detected an
error, identify the cause of the error and take action.
• Correct the target IP address of transient data, and retry the
operation.
• Write the network parameter to the CPU module again.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
• Write the network parameter to the CPU module again.
• If the error occurs again even after taking the above, please
consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Please consult your local Mitsubishi representative.
Detailed information 1
Detailed information 2
8 TROUBLESHOOTING
161
8.5 List of Error Codes
8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec iq-f fx5-40ssc-gMelsec iq-f fx5-80ssc-g

Table of Contents