"CC-Link IE TSN/CC-Link IE Field Diagnostics" window
Network map
In this manual, "Authentication Class" is described as "CC-Link IE TSN Class".
Item
Select
Module
Diagnostics
[Change Module]
Destination
button
Select Station
Monitor
[Start Monitoring]
Status
button
[Stop Monitoring]
button
[Update] button
[Legend] button
St. Info
Network
Total Device Stations
Status
(Parameter)
Total Device Stations
(Connected)
Communication Cycle
Interval Setting value
Number of Station
Errors Detected
Change IP Address
Display
Network map
Data Unlinked
Selected Station Communication
Status Monitor
Operation
[Communication Test]
Test
button
Selected
[Remote Operation]
Station
button
Operation
8 TROUBLESHOOTING
132
8.3 Checking the Network Status
Description
The Motion module under diagnostics is displayed.
Allows to change the target Motion module when multiple Motion modules are mounted.
Selects the station number of the station to be diagnosed.
A station to be diagnosed can also be selected by clicking the module icon displayed in the network map.
Starts monitoring the CC-Link IE TSN/CC-Link IE Field diagnostics.
Stops monitoring the CC-Link IE TSN/CC-Link IE Field diagnostics.
If the actual network configuration and network map of the "CC-Link IE TSN/CC-Link IE Field Diagnostics" window are
inconsistent, the network map update is executed so they are matched. A data link error may momentarily occur in all
the stations and outputs of the connected device stations may turn off since all stations on the network will be
reconnected when executing the network map update. Set output data if needed.
Displays the meaning of icons displayed in the "CC-Link IE TSN/CC-Link IE Field Diagnostics" window.
The display name of the device station can be selected from "By Device Name", "By Station Type", "By Model Name",
or "By IP Address". (Default: "By Device Name")
"By Device Name" displays the information entered in "Alias" of "Network Configuration Settings" under "Basic
Settings". The station type is displayed when the "Alias" is not entered.
Displays the total number of device stations set in "Network Configuration Settings" under "Basic Settings".
Stores the total number of device stations (number of device stations) that are actually connected by data link in the
CC-Link IE TSN.
The communication cycle interval set in "Communication Period Setting" under "Basic Settings" of the master station is
displayed. (s unit)
Indicates the number of error stations in the displayed network.
Allows to select from "DEC" or "HEX" for IP address display on the selected communication status monitor and
network map. (Default: Decimal)
Indicates the CC-Link IE TSN structure and the status of each station. ( Page 133 Network map)
Displays a disconnected station that has been set in "Network Configuration Settings" under "Basic Settings" but has
not yet performed data link. Reserved stations or error invalid stations are also included.
Displays status of the station selected in "Network Status". ( Page 135 Selected Station Communication Status
Monitor)
Performs a communication test. ( Page 136 Communication test)
Performs remote operations (such as RUN, STOP, and RESET operations) on the CPU module. ( Page 137
Remote operation)