*1 If the setting on the "Specify Connection Destination Connection" window of the engineering tool is as follows, remote operation cannot
be executed with "All Stations Specified".
Connection via Ethernet with the selections "Ethernet Board" for the personal computer-side I/F and "CC IE TSN/Field Module" for the
programmable controller-side I/F
When starting the CC-Link IE TSN/CC-Link IE Field diagnostics by specifying "Other Station (Single Network)"
or "Other Station (Co-existence Network)" in "Other Station Setting" on the "Specify Connection Destination
Connection" window, the following restrictions apply.
• A communication test cannot be used.
• If MELSECNET/H, multidrop connection of serial communication modules, an interface board for a personal
computer, or network modules of the MELSEC-Q/L series are included in the communication path,
diagnostics cannot start.
Usage methods
The following describes how to use the CC-Link IE TSN/CC-Link IE Field diagnostics.
1.
Connect the engineering tool to the CPU module.
If a device station cannot be monitored due to an error such as Ethernet cable disconnection, directly connect the engineering
tool to the device station.
2.
Start the CC-Link IE TSN/CC-Link IE Field diagnostics.
[Diagnostics]  [CC-Link IE TSN/CC-Link IE Field Diagnostics]
3.
When the following window opens, select the Motion module to be diagnosed and click the [OK] button to start the CC-
Link IE TSN/CC-Link IE Field diagnostics.
Modules are listed in the order configured in module information.
8 TROUBLESHOOTING
130
8.3 Checking the Network Status