d-Color MF4003/MF3303
5.1.9 Cleaning of the registration roller
1. Open the right door.
2. Remove the IDC sensor assy.
F.4.7.1 IDC sensor (IDCS1)
[1]
5.1.10 Cleaning of the area around the waste toner collecting port
1. Remove the waste toner bottle.
E.3.1.9 Replacing the waster toner bottle
[1]
5.1.11 Cleaning of the 2nd image transfer entrance guide
1. Open the right door.
2. Remove the IDC sensor assy.
F.4.7.1 IDC sensor (IDCS1)
[1]
5.1.12 Cleaning of the IDC sensor window
1. Open the right door.
2. Remove the IDC sensor assy.
F.4.7.1 IDC sensor (IDCS1)
Y119930-3
3. Clean the PH window by putting the PH window cleaning jig [1] back and forth
a couple times.
[1]
3. Using a cleaning pad with alcohol, wipe the registration roller [1] clean of dirt.
2. Wipe the areas [1] around the waste toner collecting port clean of spilled toner
and dirt.
3. Wipe the 2nd transfer entrance guide [1] clean of dirt.
E MAINTENANCE > 5. Cleaning/Lubrication procedure
E-19