d-Color MF4003/MF3303
Error code
3004
http request result problem
• Receive error occurred. Or wrong request URL was specified.
3005
http request result problem
• Content-Length or receive size exceeded the specified max.
transfer size. Message body size was too large.
3006
http request result problem
• Due to reset, process was stopped. Or message body size
exceeded the specified max. transfer size.
3007
http request result problem
• Internal error occurred. Or due to internal reset, process was
stopped.
3008
http request result problem
• Connection to WebDAV server failed.
3009
http request result problem
• Error occurred during transmission to the WebDAV server.
3010
http request result problem
• Time out occurred during transmission to the WebDAV server.
3011
http request result problem
• Connection to the proxy server failed.
3012
http request result problem
• The proxy server refused CONNECT request.
3013
http request result problem
• The proxy server was set to enabled, but the proxy server host
was not set.
3014
http request result problem
• Proxy server authentication failed.
3015
http request result problem
• Other error was returned from the proxy server.
3016
http request result problem
• Internal error occurred.
3017
http request result problem
• As the device application specified MIO_REQBODY_ERROR,
process was stopped.
4103
After the main power switch is switched ON, HTTP communication is
attempted under the condition where HTTP communication is not
ready.
5###
MIO detects error when sending an attached file.
6###
MIO detects error during a sending sequence.
7000
Failure occurs when a certificate for product authentication is acquired
from a USB device.
Y119930-3
Contents
I-37
I SERVICE MODE > 8. CS Remote
Solution
• Password
Wait for a while and try transmitting again.
Check the SMTP server and POP3 server on
user side.
Check the SMTP server and POP3 server on
user side.
Acquire a new certificate (within 6 days after
the issue).