16.6 Communication
Protocol
Setting item
V8/V34 Protocol
To set whether or not to use the V.8/V.34 protocol.
V17 EP TONE
Whether the EP tone (Echo Protect: 2100Hz) is added to the top of the training
signal.
This setting is displayed only when "Line1" is selected.
V29 EP TONE
Whether the EP tone (Echo Protect: 2100Hz) is added to the top of the training
signal.
This setting is displayed only when "Line1" is selected.
V17 Selection Mode
V.34 is not used when a dash (-) is added at the top of dial number.
"-"
This setting is displayed only when "Line1" is selected.
ANSam Send Time
To set the transmission time for the V.8 protocol signal ANSam.
Usually not need to be changed.
This setting is displayed only when "Line1" is selected.
Int'l Comm. Function
Setting item
Foreign
To set whether or not to use the mode that employs the number of DIS waiting
Communication
times.
Function
No. of DIS Waiting
To set the number of DIS waiting times.
Times at Foreign
Communication
V34 Speed
To set the V.34 international communication mode speed.
V17 Speed
To set the V.17 international communication mode speed.
V29 Speed
To set the V.29 international communication mode speed.
TIMER1
Setting item
T1
T1 timer (T.30 standard)
• Calling: Designate by the response waiting timer
• Called: Starts after DIS is output. The waiting time until DCS is received.
Response waiting timer (55sec)
• Calling: Starts after dialing. Until CED is received.
DCS-TCF DELAY
To set the delay time between DCS and TCF. (*1)
CED-DIS DELAY
To set the delay time between CED and DIS. (*2)
PIX-PMC DELAY
To set the delay time between PIX and PMC. (*3)
• *1: DCS-TCF DELAY
CED
DIS
• *2: CED-DIS DELAY
CED
DIS
• *3: PIX-PMC DELAY
Y119930-3
Contents
Contents
Contents
DCS TCF
PIX
PMC
PMC: Post Message Command
DCS
TCF
PIX
PMC
PMC: Post Message Command
I-89
I SERVICE MODE > 16. FAX
Setting value
Default setting
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1.0 to 5.5 s
4.0 s
(Step: 0.5 s)
Setting value
Default setting
ON
OFF
1
2
16800 to 33600 bps
28800 bps
(Step: 2400 bps)
7200 to 14400 bps
7200 bps
(Step: 2400 bps)
2400 to 9600 bps
4800 bps
(Step: 2400 bps)
Setting value
Default setting
30 to 90 s
(Step: 5 s)
50 to 150 ms
80 ms
(Step: 10 ms)
50 to 150 ms
80 ms
(Step: 10 ms)
50 to 150 ms
80 ms
(Step: 10 ms)