Items
Line 1
Ringer detection
000E00C6 000E01D6 000E02E6 000E03F6 7-0 Ringer detection frequency
frequency upper
limits
Ringer detection
000E00C7 000E01D7 000E02E7 000E03F7 7-0 Ringer detection frequency
frequency lower
limits
Ringer ON time
000E00C8 000E01D8 000E02E8 000E03F8 7-0 Ringer ON time max. value
max. value
Ringer ON time
000E00C9 000E01D9 000E02E9 000E03F9 7-0 Ringer ON time min. value
min. value
Ringer OFF time
000E00CA 000E01DA 000E02EA 000E03FA 7-0 Ringer OFF time max. value
max. value
Ringer OFF time
000E00CB 000E01DB 000E02EB 000E03FB 7-0 Ringer OFF time min. value
min. value
DRPD ringer ON
000E00CC 000E01DC 000E02EC 000E03FC 7-0 DRPD ringer ON time max.
time max. value
DRPD ringer ON
000E00CD 000E01DD 000E02ED 000E03FD 7-0 DRPD ringer ON time min.
time min. value
DRPD ringer OFF
000E00CE 000E01DE 000E02EE 000E03FE 7-0 DRPD ringer OFF time max.
time max. value
DRPD ringer OFF
000E00CF 000E01DF 000E02EF 000E03FF 7-0 DRPD ringer OFF time min.
time min. value
DRPD max.
000E00D0 000E01E0
adjustment value
for max. OFF time
DRPD min.
000E00D1 000E01E1
adjustment value
for max. OFF time
DRPD single ring
000E00D2 000E01E2
stop detection time
DRPD double ring
000E00D3 000E01E3
stop detection time
DRPD Triple1 ring
000E00D4 000E01E4
stop detection time
DRPD Triple2 ring
000E00D5 000E01E5
stop detection time
DRPD NZ-DA1 ring
000E00D6 000E01E6
stop detection time
DRPD NZ-DA2 ring
000E00D7 000E01E7
stop detection time
DRPD NZ-DA3 ring
000E00D8 000E01E8
stop detection time
DRPD NZ-DA4 ring
000E00D9 000E01E9
stop detection time
Custom 1st ringer
000E00DA 000E01EA 000E02FA 000E040A 7-0 Custom 1st ringer ON time
ON time specified
value
Custom 1st ringer
000E00DB 000E01EB 000E02FB 000E040B 7-0 Custom 1st ringer OFF time
OFF time specified
value
Custom 2nd ringer
000E00DC 000E01EC 000E02FC 000E040C 7-0 Custom 2nd ringer ON time
ON time specified
value
Service Manual
Address
Line 2
Line 3
Line 4
000E02F0
000E0400 7-0 DRPD max. adjustment value
000E02F1
000E0401 7-0 DRPD ringer min. adjustment
000E02F2
000E0402 7-0 DRPD single ring stop
000E02F3
000E0403 7-0 DRPD double ring stop
000E02F4
000E0404 7-0 DRPD Triple1 ring stop
000E02F5
000E0405 7-0 DRPD Triple2 ring stop
000E02F6
000E0406 7-0 DRPD NZ-DA1 ring stop
000E02F7
000E0407 7-0 DRPD NZ-DA2 ring stop
000E02F8
000E0408 7-0 DRPD NZ-DA3 ring stop
000E02F9
000E0409 7-0 DRPD NZ-DA4 ring stop
Data
Bit
Contents
* Normal conforms to
Ringer[2] through [5] as
usual.
* For DRPD, configure the
margin time (min, max) from
the standard time (*1).
upper limit (unit: 1 Hz)
lower limits (unit: 1 Hz)
(unit: 20 ms)
(unit: 20 ms)
(unit: 100 ms)
(unit: 100 ms)
value (unit: 20 ms)
value (unit: 20 ms)
value (unit: 20 ms)
value (unit: 20 ms)
for max. OFF time (unit: 100
ms)
value for max. OFF time (unit:
100 ms)
detection time (unit: 100 ms)
detection time (unit: 100 ms)
detection time (unit: 100 ms)
detection time (unit: 100 ms)
detection time (unit: 100 ms)
detection time (unit: 100 ms)
detection time (unit: 100 ms)
detection time (unit: 100 ms)
specified value (unit: 100 ms)
specified value (unit: 100 ms)
specified value (unit: 100 ms)
I-110
I SERVICE MODE > 16. FAX
Default
Setting
Data
70 Hz
01000110
12 Hz
00001100
0 ms
00000000
200 ms (JP/US)
00001010
160 ms (EU)
(JP/US)
00001000
(EU)
6000 ms (JP/US)
00111100
7000 ms (EU)
(JP/US)
01000110
(EU)
200 ms (JP)
00000010
0 ms (US/EU)
(JP)
00000000
(US/EU)
180 ms
00001001
180 ms
00001001
180 ms
00001001
180 ms
00001001
500 ms
00000101
500 ms
00000101
8000 ms
01010000
8000 ms
01010000
8000 ms
01010000
8000 ms
01010000
6000 ms
00111100
6000 ms
00111100
5000 ms
00110010
5000 ms
00110010
0 ms
00000000
0 ms
00000000
0 ms
00000000
Y119930-3