Olivetti d-Color MF4003 Service Manual page 466

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
Rank
C
Trouble detection condition
Trouble isolation
-
Relevant electrical parts
Procedure
1. Check CPUB for proper installation and correct as necessary.
2. Rewrite the firmware.
3.
Replace CPUB.
4.
Replace BASEB.
3.18.25  CD3C0
Contents
Trouble type
CD3C0: New board detection
Rank
C
Trouble detection condition The board is replaced with a new one.
Trouble isolation
-
Relevant electrical parts
-
Procedure
1. Wait until "Recover Data" appears. (MFP will reboot maximum 2 times by itself, it may take 5 minutes.) Touch the "Recover Data" button
and follow the instructions that appear on the control panel to restore (backup) data.
3.18.26  CD401, CD402, CD403, CD404, CD405, CD406, CD407, CD411, CD412, CD413
Contents
Trouble type
Rank
C
Trouble detection condition When abnormality is found in the communication of controller.
Trouble isolation
-
Relevant electrical parts
Procedure
1. Check whether there is a strong electromagnetic noise source near the main body.
2. Check the connector between the control panel-BASEB CN7 for proper connection and correct as necessary.
3. Check CPUB for proper installation and correct as necessary.
4.
Replace CPUB.
5.
Replace BASEB.
3.18.27  CD601, CD602, CD603
Contents
Trouble type
CD601, CD602, CD603: Trouble related to security
Rank
-
Trouble detection condition -
Trouble isolation
-
Procedure
1. Turn OFF the main power switch, wait for 10 sec. or more, and turn ON the main power switch. If the above actions do not solve the
problem, contact OLI.
Service Manual
• CD3B5: DB definition file error
• CD3B1: When starting the MFP, PostgreSQL server startup has not been successful.
• CD3B3: When starting the MFP, SQL DB access fails in PostgreSQL server startup processing.
• CD3B4: When starting the MFP, SQL DB definition file does not exist in PostgreSQL server startup
processing.
• CD3B5: When starting the MFP, there is an error in SQL DB definition file in PostgreSQL server startup
processing.
• CPU board (CPUB)
• Base board (BASEB)
• CD401: NACK command incorrect
• CD402: ACK command incorrect
• CD403: Checksum error
• CD404: Receiving packet incorrect
• CD405: Receiving packet analysis error
• CD406: ACK receiving timeout
• CD407: Retransmission timeout
• CD411: Touch panel board error
• CD412: Touch panel type mismatch
• CD413: Electrostatic touch panel operation mode error
• Control panel
• CPU board (CPUB)
• Base board (BASEB)
L TROUBLESHOOTING > 3. TROUBLE CODE
L-68