Olivetti d-Color MF4003 Service Manual page 476

Multifunction digital copier
Hide thumbs Also See for d-Color MF4003:
Table of Contents

Advertisement

d-Color MF4003/MF3303
Reason of error
STRGB error (data failure)
Relevant electrical parts
Storage board (STRGB)
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of STRGB if faulty.
3. Select [Service Mode] -> [State Confirmation] -> [Memory/Storage Adjustment] -> [Format] -> [Logical Format] and perform the function.
4.
Replace STRGB.
4.9  E3-1
Contents
Error code
E3-1
Target device
I2C
Diagnosis item
TPM
Reason of error
Connection failure
Parts defect
Relevant electrical parts
TPM board (TPMB)
CPU board (CPUB)
Base board (BASEB)
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of TPMB if faulty.
3. Correct the mounting of CPUB if faulty.
4. Correct the mounting of BASEB or the connection of connectors if faulty.
5.
Replace TPMB.
6.
Replace CPUB.
7.
Replace BASEB.
4.10  E3-2
Contents
Error code
E3-2
Target device
I2C
Diagnosis item
AUDIO (control)
Reason of error
Connection failure
Parts defect
Relevant electrical parts
CPU board (CPUB)
Base board (BASEB)
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of CPUB if faulty.
3. Correct the mounting of BASEB or the connection of connectors if faulty.
4.
Replace CPUB.
5.
Replace BASEB.
4.11  E3-3
Contents
Error code
E3-3
Target device
I2C
Diagnosis item
PS-CPU
Reason of error
Connection failure
Parts defect
Relevant electrical parts
CPU board (CPUB)
Base board (BASEB)
Corrective action procedure
1. Turn OFF the main power switch and unplug the power cord. Connect the power cord after 15 sec. or more, and turn ON the main power
switch.
2. Correct the mounting of CPUB if faulty.
3. Correct the mounting of BASEB or the connection of connectors if faulty.
4.
Replace CPUB.
5.
Replace BASEB.
Service Manual
L TROUBLESHOOTING > 4. TROUBLESHOOTING USING SELF-DIAG. (FULL)
L-78
Y119930-3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-color mf3303

Table of Contents