1105
Unable to delete label; used by emulation analyzer: <label>
Cause: This error occurs when you attempt to delete an emulation trace label
which is currently being used as a qualifier in the emulation trace specification or is
currently specified in the emulation trace format.
Action: You stop the trace or must change the trace command before you can
delete the label.
1106
Unable to delete label; used by external state analyzer: <label>
Cause: This error occurs when you attempt to delete an external trace label which
is currently being used as a qualifier in the external state trace specification or is
currently specified in the external trace format.
Action: You stop the trace or must change the trace command before you can
delete the label.
1107
Unable to delete label; used by external timing analyzer: <label>
Cause: This error occurs when you attempt to delete an external trace label which
is currently being used as a qualifier in the external timing trace specification.
Action: Remove the label from the external timing analyzer specifications, and
then delete the label.
1108
Unable to redefine label; used by emulation analyzer: <label>
Cause: This error occurs when you attempt to redefine an emulation trace label
which is currently used as a qualifier in the emulation trace specification.
Action: You stop the trace or must change the trace command before you can
redefine the label.
1109
Unable to redefine label; used by external state analyzer: <label>
Cause: This error occurs when you attempt to redefine an external trace label
which is currently used as a qualifier in the external state trace specification.
Action: You stop the trace or must change the trace command before you can
redefine the label.