Chapter 13: Error Messages
Terminal Interface Messages
628
Guarded memory break: %s"
Cause: A memory access to a location mapped as guarded memory has occurred
during execution of the user program.
Action: Investigate the cause of the guarded memory access by the user program.
628
Write to ROM break: %s"
Cause: When the emulator is configured to break on writes to ROM, a memory
write access to a location mapped as ROM has occurred during execution of the
user program.
Action: Investigate the cause of the write to ROM by the user program. You can
configure the emulator so that it does not break on writes to ROM.
630
Register access aborted
Cause: Occurs when a <CTRL>c is entered during register display.
631
Unable to read registers in class: %s
Cause: The emulator was unable to read the registers you requested.
Action: To resolve this, you must look at the other status messages displayed.
Most likely, the emulator was unable to break to the monitor to perform the register
read. See message 608.
632
Unable to modify register: %s=%s
Cause: The emulator was unable to modify the register you requested.
Action: To resolve this, you must look at the other status messages displayed. It's
likely that emulator was unable to break to the monitor to perform the register
modification. See message 608.
634
Display register failed: %s
Cause: The emulator was unable to display the register you requested.
Action: To resolve this, you must look at the other status messages displayed. It's
likely that emulator was unable to break to the monitor to perform the register
display. See message 608.