Chapter 13: Error Messages
Terminal Interface Messages
1110
Unable to redefine label; used by external timing analyzer: <label>
Cause: This error occurs when you attempt to redefine an emulation or external
trace label which is currently being used as a qualifier in the external timing trace
specification.
Action: Remove the label from the external timing analyzer specifications, and
then redefine the label.
1301
External label in use: <label>
Cause: This error occurs when you attempt to select the external analyzer's
independent state mode while an external trace label is currently used as a qualifier
in the emulation analyzer trace specification.
Action: Remove any external trace label qualifiers from emulation trace
specifications before selecting the external analyzer's independent state mode.
1304
Analyzer trace running
Cause: This error occurs when you attempt to change the external analyzer mode
while a trace is in progress.
Action: Halt the trace before changing the external analyzer mode.
1305
CMB execute; emulation trace started
Cause: This status message informs you that an emulation trace measurement has
started as a result of a CMB execute signal (as specified by the specify trace
command).
2021
Period not in 1/2/5 sequence: <period>
Cause: This error message occurs when the external timing sample period is not in
a 1/2/5 sequence; for example, 10ns, 20ns, 50ns, 100ns, 200ns, 500ns, 1us, 2us,
5us, etc. Some examples of invalid sample period specifications are: 12ns, 18ns,
25ns, 60ns, 80ns, etc.
Action: Use a number in the 1/2/5 sequence when specifying the external timing
sample period.