Chapter 5: Plugging into a Target System
Connecting the Emulator Probe

Step 2. Connect the probe to the target system

CAUTION
Possible Damage to the Emulator Probe. A pin extender is included with the
emulator probe. Do not use the probe without a pin extender (that is, an extra
PGA socket) installed. Replacing a broken pin extender is much less expensive
than replacing the emulator probe adapter.
The use of more than one pin extender is discouraged, unless it is necessary for
mechanical clearance reasons, because pin extenders cause signal quality
degradation.
PGA sockets are available from HP as HP part number 1200-1318. A MacKenzie
Technology PGA-100M-003B1-1324 socket should also be suitable.