Graphical/Softkey Interface Messages - Unnumbered
Invalid answer in <CONFIGURATION FILENAME> ignored
Cause: You must provide acceptable responses to questions in the configuration file
(file.EA). The emulator ignored the incorrect response. Incorrect responses may
appear in configuration files when you have saved the configuration to a file, edited
it later, and tried reloading it into the emulator. This may also occur if you have
loaded a configuration file that you created while using another emulator, and the
response differs from the response required for this emulator.
Action: Examine your configuration file to check for inappropriate responses to
configuration file questions.
Inverse assembly file <INVERSE ASSEMBLER FILENAME> could not be
loaded
Inverse assembly file <INVERSE ASSEMBLER FILENAME> not found,
<filename>
Inverse assembly not available
Cause: The file does not exist.
Action: Reload your interface and/or real-time operating system software.
Inverse assembly not available
Cause: The inverse assembler for your emulator is missing.
Action: Verify proper software installation.
Joining session already in progress, continue file loaded
Cause: This is a status message. When operating the emulator in multiple
windows, a new emulation session is "joined" to a current session. In this case, the
new session was able to continue because the continue file loaded properly.
Joining session already in progress, user interface defaulted
Cause: When operating the emulator in multiple windows, a new emulation session
is "joined" to a current session. In this case, the new session used the user interface
default selections.