Configuring the External Analyzer
Answer "demux" to specify the true demultiplexing mode. In this mode, only the
lower eight external channels (0-7) are used. The slave clock (as specified by your
answers to the next four questions) latches these bits and the emulation clock
samples the same channels again. The latched bits show up as bits 0-7 in the trace
data, and the second sample shows up as bits 8-15 (see the figure below).