Chapter 13: Error Messages
Graphical/Softkey Interface Messages - Unnumbered
Load aborted
Cause: While loading a file into the emulator, an event occurred that caused the
host system to stop the load process.
Action: Use the display error_log command to view any errors. If the problem
persists, make sure the host system and emulator are operating properly, and that
you are trying to load an acceptable file. See the "Emulator/Analyzer Interface
Commands" chapter for information about the load command.
Load completed with errors
Cause: While loading a file into the emulator, one or more events occurred that
caused errors during the load process.
Action: Use the display error_log command to view any errors. You may need to
modify the configuration and map memory before you load the file again. If the
problem persists, make sure the host system and emulator are operating properly,
and that you are trying to load an acceptable file.
Measurement system not found
Cause: You tried to end the current emulation session and select another
measurement system module which could not be located by the host system.
Action: Either try the end select measurement_system command again or end and
release the emulation session.
Memory allocation failed, ending released
Cause: This is a fatal system error because the emulation session was unable to
allocate memory.
Action: You may need to reconfigure your UNIX kernel to increase the per process
maximum memory limit and available swap space. Reboot your UNIX system and
try starting a new session again.
Memory block list unreadable
Memory range overflow
Cause: A modify memory command is attempted that would cross physical 0.