To drive the external analyzer trigger signal to
the BNC connector
1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "receive" to the "Should BNC drive or receive Trig2?" question.
4 Answer "drive" to the "Should External Analyzer drive or receive Trig2?" question.

To break emulator execution on signal from CMB

1 Enter the modify configuration command.
2 Answer "yes" to the "Modify interactive measurement specification?" question.
3 Answer "drive" to the "Should CMBT drive or receive Trig1?" question.
You could also break emulator execution on a trigger signal from the CMB over the
trig2 internal line by specifying that the CMB should drive trig2 and that the
emulator break should receive trig2.
Chapter 10: Making Coordinated Measurements
Using Trigger Signals