Chapter 9: Using the External State Analyzer
Setting Up the External Analyzer
To connect the external analyzer probe to the
target system
1 Assemble the Analyzer Probe. The analyzer probe is a two-piece assembly, consisting of ribbon cable
and 18 probe wires (16 data channels and the J and K clock inputs) attached to a connector. Either end of
the ribbon cable may be connected to the 18 wire connector, and the connectors are keyed so they may
only be attached one way. Align the key of the ribbon cable connector with the slot in the 18 wire
connector, and firmly press the connectors together.