Chapter 4 Specifications; General Specifications - Mitsubishi Electric GOT SIMPLE Series Operation Manual

Hide thumbs Also See for GOT SIMPLE Series:
Table of Contents

Advertisement

4
SPECIFICATIONS
• Page 45 General Specifications
• Page 46 Performance Specifications
• Page 48 Specifications of Power Supply Section
• Page 49 Battery Specifications
4.1

General Specifications

This section describes the general specifications of the GOT.
GS2512-WXTBD
Item
*1
Operating ambient temperature
Storage ambient temperature
Operating ambient humidity
Storage ambient humidity
Vibration resistance
Shock resistance
Operating atmosphere
*2
Operating altitude
Installation location
*3
Overvoltage category
*4
Pollution degree
Cooling method
Grounding
*1 Indicates the temperature inside the enclosure of the control panel on which the GOT is installed.
*2 Do not use or store the GOT under a pressure higher than the atmospheric pressure at an altitude 0 m.
Doing so may cause a malfunction.
Air purging by applying pressure to the control panel may create clearance between the surface sheet and the touch panel. This may
cause the touch panel to be not sensitive enough or the sheet to come off.
*3 This indicates the power distribution section to which the equipment is assumed to be connected, between the public power grid and the
machinery within the premises.
Category II applies to equipment for which electrical power is supplied from fixed facilities.
The withstand surge voltage for the equipment with the rated voltage up to 300 V is 2500 V.
*4 This indicates the occurrence rate of conductive material in an environment where a device is used. Pollution degree 2 indicates an
environment where only non-conductive pollution occurs normally and a temporary conductivity caused by condensation shall be
expected depending on the conditions.
Specifications
0 °C to 50 °C
-20°C to 60°C
10% RH to 90% RH, non-condensing
10% RH to 90% RH, non-condensing
Compliant with JIS B3502
and IEC 61131-2
Under intermittent
vibration
Under continuous
vibration
Compliant with JIS B3502 and IEC 61131-2 (147 m/s
No greasy fumes, corrosive gas, flammable gas, excessive conductive dust, and direct sunlight (as well as at storage)
2000 m or less
Inside control panel
II or less
2 or less
Self-cooling
Grounding with a ground resistance of 100 Ω or less by using a ground cable that has a cross-sectional area of 2 mm
more. If impossible, connect the ground cable to the control panel.
Frequency
Acceleration
Half amplitude
5 Hz to 8.4 Hz
-
3.5 mm
2
8.4 Hz to 150 Hz
9.8m/s
-
5 Hz to 8.4 Hz
-
1.75 mm
2
8.4 Hz to 150 Hz
4.9m/s
-
2
(15 G), 3 times in each X, Y, or Z direction)
4.1 General Specifications
Sweep count
X, Y, or Z
10 times in
each direction
-
2
or
4 SPECIFICATIONS