Detail information setting operation
For Standard I/F-1(RS422) and Standard I/F-2(RS232)
Touch [Driver display BOX].
1.
Touch each driver display box of the standard I/F-1 and standard I/F-
2.
2.
The screen jumps to the detailed information screen and the
communication parameter will appear.
3.
Touch the numerical values of baud rate to switch them repeatedly.
Ex. 4800bps
9600bps
The numerical values are set using the ten-key depending on the setting.
"0" to "9":
Use these keys to enter numerical values. Enter "0" to disable the screen
saver function.
"ESC":
Closes the ten-key window without saving any value entered.
"AC":
Deletes the entire string of numerical characters that are being entered.
"DEL":
Deletes a digit from a string of numerical characters that are being
entered.
"ENT":
Enters the value for the clock that has been entered and closes the ten-
key pad window.
"+/-":
Switches between positive and negative values. (Only positive values are
valid for the clock setting.)
"." :
Invalid key (not used)
23 COMMUNICATION INTERFACE SETTING (COMMUNICATION SETTING)
19200bps
23.1 Standard I/F Setting
23