Specifications

System configuration
This section describes the system configuration of the MELSEC-FX list editor.
For the setting method in each connection form, used communication unit/cable and cautions on connection form, refer to the
following manual.
GOT2000 Series Connection Manual For GT Works3 Version1
Controllers that can be edited with the MELSEC-FX list editor
*1
Target controller
: FXCPU
*1 FX list editor is not applicable to for MELSEC iQ-F series.
Connection type
This function can be used in the following connection types.
( : Available, : Unavailable)
Function
Name
MELSEC-FX list editor
*1 MELSEC-FX list editor cannot be used when using CC-Link IE field network Ethernet adapter.
*2 Available only when using FX3 series.
Functions list and monitor conditions
The following shows the memory that can be monitored by the MELSEC-FX list editor and the FX PLC status conditions.
( : Can be monitored : Can be monitored under certain conditions : Cannot be monitored)
Function
Reading
Displaying sequence
sequence
programs
programs
Searching commands/
devices
Writing
Writing commands
sequence
Changing operands/
programs
set values
Inserting commands
Deleting commands
Sequence program all clear
PLC diagnostics
Parameter setting
Display
Setting
Keyword
*1 The operation is available only when the protect switch is OFF.
*2 The available memory differs depending on the FX PLC being used.
For details, refer to the following.
The hardware manual of the FX PLC being used
28 GOT SELF CHECK (DEBUG)
350
28.2 FX List Editor
Description
Sequence program writing, parameter setting,
PLC diagnostics and keyword registration, etc.
Memory that can be monitored
Built-in
RAM
memory
memory
cassette
Connection type between GOT and PLC
Direct CPU connection
(serial)
*2
EEPROM
EPROM
memory
memory
cassette,
cassette
flash memory
cassette
*1
*1
Ethernet connection
*2
FX PLC
Reference
status
Page 357 Displaying
RUN/STOP
sequence programs
Page 359 Searching
commands/devices
For Stop only
Page 361 Writing commands
Page 366 Deleting
commands
Page 361 Writing commands
Page 366 Deleting
commands
Page 367 Sequence program
all clear
Page 368 PLC diagnostics
RUN/STOP
Page 370 Parameter setting
For Stop only
Page 372 Keyword
RUN/STOP