Description - GE Dash 2500 Operator's Manual

Patient monitor
Hide thumbs Also See for Dash 2500:
Table of Contents

Advertisement

Description

®
*MASIMO SET
is a trademark of MASIMO Corporation. Possession or purchase of this device does not convey any express or implied license to
use the device with replacement parts which would, alone, or in combination with this device, fall within the scope of one or more of the patents
relating to the device.
2042480-001 C
MASIMO SET® SpO2: Description
®
The SpO
parameter in the Dash 2500 Patient Monitor is available in two
2
different leading technologies: NELLCOR
technology logo will be on the side of the Monitor next to the SpO
This section refers to MASIMO SET
Functional oxygen saturation (SpO
2500 Patient Monitor by a pulse oximetry parameter that provides continuous,
noninvasive measurements of SpO
plethysmographic waveform, and a signal strength bar. The signal strength bar
is an indication of the confidence associated with the saturation measurement
and timing of the pulse. To begin SpO
SpO
port, place the SpO
2
2
automatically.
Functional SpO
is the ratio of oxygenated hemoglobin to hemoglobin that is
2
capable of transporting oxygen. This ratio, expressed as a percentage, is shown
in the SpO
field of the screen and is updated with each heart beat. The
2
percentage of SpO
is also indicated by a pulse tone that is activated by the
2
Adjust QRS volume option in the HR/Pulse menu. The pitch frequency of the
tone is proportional to the oxygen saturation value: highest at 100% saturation
and lower as the level of saturation falls.
Pulse Rate derived from SpO
View SpO2 PR? option is set to yes:
When pulse rate (PR) is derived from SpO
vital signs field.
NOTE: Unless PR is the source for the HR/Pulse, it is only trended when the
View SpO2 PR? option is set to yes.
View SpO2 PR? option is set to no:
PR will not appear in the SpO
for the HR/Pulse.
When SpO
is the source for the HR/Pulse:
2
Pulse rate derived from SpO
appear for PR in the SpO
The SpO
parameter has audible and visible alarms to let you know when the
2
SpO
levels are outside the alarm limits. If the View SpO2 PR? option is set to yes,
2
audible and visible alarms for the pulse rate (derived from SpO
The alarm limits for PR are the same as those for HR/Pulse.
Dash 2500 Patient Monitor
®
and MASIMO SET
®
SpO
technology.
2
) of arterial blood is monitored in the Dash
2
and can provide displays of pulse rate, a
2
monitoring, plug the sensor cable into the
2
sensor on the patient's finger, and monitoring begins
appears under the following conditions:
2
, the value appears in the SpO
2
vital signs field, but SpO
2
appears only in the HR vital signs field (dashes
2
vital signs field).
2
®
. The SpO
2
connector.
2
2
is still a valid source
2
) are activated.
2
13-3

Hide quick links: