Smartlinx; Dolphin Plus - Siemens MAG 1100 Operating Instructions Manual

Electromagnetic flowmeters
Table of Contents

Advertisement

Parameter
P770
P771
P772
P773
P774
P775
P778
P782

SmartLinx

Other protocols are available through optional SmartLinx communications modules.
Details on how to install and program these modules are contained in the SmartLinx
documentation.

Dolphin Plus

Dolphin Plus software makes it easy to record and compare parameter sets for all the
MultiRangers in your company. Dolphin Plus uses a proprietary protocol called
communicate with Siemens Milltronics instruments. This protocol is set when P770 = 1.
By default the settings for port 1 (RJ-11 connection) and Dolphin Plus match. These
settings are:
Parameter
P770
P772
P773
P774
P775
7ML19981FB05
MultiRanger 100/200 - INSTRUCTION MANUAL
Index
Value
2
3
2
1
2
9.6
2
0
2
8
2
1
2
0
2
0
Index
Value
1
1
1
115.2
1
0
1
8
1
1
Description
Modbus RTU slave
Network address, only used for RS-485
Data rate of 9600 baud
No parity, common setting
8 data bits, common setting
1 stop bit, common setting
No modem connected
Index parameter values globally
Description
Dolphin
Data rate of 115.2 Kilo baud
No parity, common setting
8 data bits, common setting
1 stop bit, common setting
Dolphin