Palmer Bowlus Flume

D/2, point of
measurement
Parameter
P600
P602
P603
P604
P605
P606
Application Information
Sized by pipe diameter D
Flume relief is trapezoidal
Designed to install directly into pipelines and manholes
Head is referenced to bottom of the throat, not bottom of the pipe
For rated flows under free flow conditions, the head is measured at a distance of
D/2 upstream from the beginning of the converging section
Page 76
MultiRanger 100/200 – INSTRUCTION MANUAL
Plan View
Flow
Side View
Index
G
2–Palmer Bowlus Flume
1
Flume width (D)
G
Maximum Head (preset = P007)
G
Maximum Flow
G
Zero Head
G
Time Units
Front View
Transducer
P603
Value
P006
P007
P605
7ML19981FB05