Remote installation -
Transmitter in 19" insert
6. Installation of transmitter
1. Fit the SENSORPROM
The SENSORPROM
®
unit is supplied with the sensor in the terminal box.
2. Mount the guide rails into the rack system as shown. Distance between guide rails is 20 TE.
Guide rails are supplied with the rack system and not with the transmitter.
3. Mount the connection board as shown.
4. Connect the cables as shown under "Electrical connection", chapter 7.
5. Insert the transmitter into the rack system.
®
memory unit on the connection board supplied with the transmitter.