Totalizer (P630 to P645) [MR 200]

The Totalizer features apply to MultiRanger 200 only.
P630 LCD Totalized Multiplier [MR 200]
Use this feature if the LCD Total increments by too large (or too small) an amount.
Primary Index
Values
Values
Related
Enter the factor (powers of 10 only) by which actual volume is divided, prior to display on
the LCD. Use a value such that the eight-digit totalizer doesn't roll over between readings.
Example:
For an LCD Total display in 1000s of volume units, enter 3.
7ML19981FB05
MultiRanger 100/200 – INSTRUCTION MANUAL
Single Point Model
Global
-3
.001
-2
.01
-1
.1
0
*
1
1
10
2
100
3
1000
4
10,000
5
100,000
6
1,000,000
7
10,000,000
LCD Totalizer (P322 and P323)
Dual Point Model
Transducer
Page 175