3. Ensure that the ventilation holes are not blocked.
4. Remove the black plastic dust caps from the fiber
5. Connect the fiber optic cables from the Peripheral
6. Connect the RJ-45 connectors to the UTP distribution
7. Connect the power cable to a convenient wall socket.
8.
Next: Install any other required Service Unit (see
"Overview" on page 29). If all the Service Units are
installed, go to "Installing Phones and Peripherals" on
page 80.
62
• Use # 12 screws that are at least 0.8 cm (1.5 in.)
long, and ensure that the screws are not fully
tightened so that the unit may be easily removed
(without the use of a tool) for servicing.
optic cables and from the connector ferrules on the
unit.
Slot FIM Carrier in the Peripheral Cabinet to the
connectors on the SUPERSET HUB unit.
panel according to the building-wiring plan.
• The wall socket is the main disconnect device and
must, therefore, be installed near the unit and be
easily accessible.
Note: The unit will be in an abnormal operation mode until
all the programming is complete.
Program the SUPERSET HUB as a DNI Line Card in the
slot where the Peripheral Slot FIM Carrier is inserted.