3Com 5500G-EI Command Reference Manual page 334

Version 3.1.x
Hide thumbs Also See for 5500G-EI:
Table of Contents

Advertisement

338
C
10: U
HAPTER
SING
stp transmit-limit
RSTP C
OMMANDS
undo stp timer max-age
View
System View
Parameter
centiseconds
:
4000. By default, the value is 2000 centiseconds.
Description
Use the
stp timer max-age
Use the
undo stp timer max-age
Maximum age is used for judging if an RSTP packet is outdated. If the value is set
too small, the spanning tree will be computed too frequently because the network
congestion may be considered as a link failure. However, if the value is set too
large, the link failure may not be discovered in time. Maximum age is related to
the network "diameter", or complexity of the switched network. The default
value, 2000, is recommended.
Related commands:
Example
To set the Max Age of the Switch to 1000 centiseconds, enter the following:
<SW5500>system-view
System View: return to User View with Ctrl+Z.
[SW5500]stp timer max-age 1000
Syntax
stp transmit-limit
undo stp transmit-limit
View
Ethernet Port View
Parameter
The maximum number of STP packets a port can send within one
packetnum
:
hello time. It ranges from 1 to 255 and defaults to 3.
Description
Use the
stp transmit-limit
packets the current port can send within one hello time.
Use the
undo stp transmit-limit
The larger the value of
more Switch resources will be used.
Specifies the maximum age in centiseconds, ranging from 600 to
command to configure the Max Age of the Switch.
command to restore the default Max Age.
stp timer forward-delay
packetnum
command to set the maximum number of STP
command to restore the default value.
is, the larger the transmission rate is. However,
packetnum
,
.
stp timer hello

Hide quick links: