5. SYSTEM MODE
Printing: 3
Stop with error ... "NO RIBBON" is displayed on the LCD.
Initial feed ... Restart
Printing: 4
Printing: 5
(*) Completely printed labels: 1

5.5.12 CALIBRATE

・ OFF:
・ ON TRANSMISSIVE:
・ ON REFLECTIVE
・ ON ALL:
・ ON TRANS+BackFeed: Auto calibration is performed with transmissive sensor, then the media is fed
・ ON REFL+BackFeed:
・ ON ALL+BackFeed:
NOTES:
1. When this parameter is enabled, an automatic calibration starts at an open/close of the print head and when
power is on.
2. When this parameter is enabled, the media length, effective print length, sensor type and whether the ribbon is
used or not, will be specified with commands, as handled as follows.
Whether the ribbon is
used or not
Sensor type
Media
Media pitch
Effective
length
Gap length
3. When the auto calibration with reflective sensor is selected, the lowest voltage detected by the reflective
sensor is considered as a black mark level. And, the sum of this voltage and the threshold fine adjustment
value will be stored as a threshold.
4. When the auto calibration with transmissive sensor is selected, the highest voltage detected by the
transmissive sensor is considered as a gap level. After subtracting the threshold fine adjustment value from
this voltage, the result will be stored as a threshold.
5. When "ON ALL" is selected, the highest voltage detected by transmissive sensor or the lowest voltage
detected by the refrective sensor is considered as a gap level. After subtracting the threshold fine adjustment
value for each sensor from this voltage, the result will be stored as a threshold.
6. The printer feeds about 160 mm long media to detect a black mark/gap and determine the threshold. When the
printer has detected more than one black marks/gaps during this 160-mm media feed, the printer measures
the media pitch and stops the automatic calibration 1 mm short of the bottom of a black mark or gap.
rd
label ... After an error is detected, printing is completed. Finished (*)
th
label ... Finished (*)
th
label ... Finished (*)
st
to 5
Auto calibration is not performed.
Auto calibration is performed with transmissive sensor.
Auto calibration is performed with reflective sensor.
Auto calibration is performed with both sensors.
backward.
Auto calibration is performed with reflective sensor, then the media is fed
backward.
Auto calibration is performed with both sensors, then the media is fed backward.
Printer behavior after automatic calibration is performed
The values obtained through the calibration will take effect until next calibration is
performed or the printer power is turned off. (Settings specified by commands are
ignored.)
The values obtained through the calibration will take effect after the calibration is
completed. Afterward, the sensor specified by a command is ignored.
After the automatic calibration is performed, the values obtained through the
calibration will take effect until next calibration is performed or the printer power is
print
turned off. (Settings specified by commands are ignored.)
th
labels
5-31
EM18-33031
5.5 SET PARAMETERS