Toshiba B-EX6 Series Maintenance Manual page 93

Table of Contents

Advertisement

5. SYSTEM MODE
*1: If "CN" is selected for the parameter clear destination, the ENERGY TYPE parameter is not displayed on the
menu and unable to be set in the system mode and user system mode. However, the initial value (See Section
5.8.3 PARAMETER CLEAR.) will be set after a parameter clear, so it is printed on the maintenance
counter/parameter settings print label.
Print condition:
Label length
Print method
Sensor type
Speed
203 dpi: B-EX6T1/T3-G
305 dpi: B-EX6T1/T3-T
Print count
Issue mode
Others
<< COUNTER >>
Item
TOTAL FEED
FEED
FEED1 to FEED4
PRINT
PRINT1 to PRINT4
Description
Range
Counting condition
[Description] Total label distance covered (cannot be cleared)
[Range] 0.0 to 3200.0 km
[Counting condition] Counted when the media feed motor is driven to feed or
print the media. (Reverse feed is also counted.)
When the power is turned off, the media distance of 50.0 cm or less may be
rounded down when backed up.
[Description] Label distance covered
[Range] 0.0 to 3200.0 km
[Counting condition] Counted when the media feed motor is driven to feed or
print the media. (Reverse feed is also counted.)
When the power is turned off, the media distance of 50.0 cm or less may be
rounded down when backed up.
[Description] History of last 4 label distances
[Range] 0.0 to 3200.0 km
[Counting condition] When the maintenance counter is RAM-cleared, the label
distance covered is saved as FEED 1. At this time, data which were saved in
FEED 1, FEED 2 and FEED 3 are re-saved as FEED 2, FEED 3, and FEED 4,
respectively.
[Description] Print distance
[Range] 0.0 to 200.0 km
[Counting condition] Counted while printing. (Reverse feed is not counted.)
B-EX6T1-G:
When the power is turned off, the print distance of 8.2 m or less is rounded
down when backed up.
B-EX6T1-T:
When the power is turned off, the print distance of 5.6 m or less is rounded
down when backed up.
[Description] History of last 4 print distances
[Range] 0.0 to 3200.0 km
[Counting condition] When the maintenance counter is RAM-cleared, the print
distance is saved as PRINT 1. At this time, data which were saved in PRINT
1, PRINT 2 and PRINT 3 are re-saved as PRINT 2, PRINT 3, and PRINT 4,
respectively.
5-7
490 mm to 530 mm (length varies on the model)
User setting
None
5 ips
5 ips
1
User setting
No rewinder motor activated
EO18-33031
5.4 DIAGNOSTIC

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents