Toshiba B-EX6 Series Maintenance Manual page 94

Table of Contents

Advertisement

5. SYSTEM MODE
CUT
HEAD U/D
RIBBON
SOLENOID
232C ERR
SYSTEM ERR
POWER FAIL
<< ADJUST >>
Item
[PC]/[KEY]
FEED
CUT
BACK
TONE (T)
TONE (D)
RIBBON TORQUE NORM
RBN (FW)
RBN (BK)
RIBBON TORQUE LOW
RBN (FW)
RBN (BK)
X ADJ.
[Description] Cut count
[Range] 0 to 1000000
[Counting condition] Every cut operation is counted.
The cut count is saved every 4 cut operations.
[Description] Head up/down count
[Range] 0 to 2000000
[Counting condition] The number of times the print head moves up and down
with the solenoid for ribbon save is counted. (A set of up and down is counted
as one.)
The head up/down count is saved every 4 head up/down operations.
[Description] Ribbon motor drive time
[Range] 0 to 2000 hours
[Counting condition] Counted when the ribbon motor is driven while media
feed or printing. (Reverse feed is also counted.)
When the power is turned off, drive time of 10 seconds or less is rounded
down when backed up.
[Description] Head-up solenoid drive time
[Range] 0 to 1000 hours
[Counting condition] Counted when the ribbon save operation is performed.
When the power is turned off, drive time of 10 seconds or less is rounded
down when backed up.
[Description] The number of times an RS-232C hardware error occurred
[Range] 0 to 255
[Counting condition] Counted when a parity error, overrun error or framing
error occurs.
[Description] The number of times a system error occurred
[Range] 0 to 15
[Counting condition] Counted when a system error occurs.
[Description] The number of times a momentary power interruption occurred
[Range] 0 to 15
[Counting condition] Counted when a momentary power interruption occurs.
Description
Feed amount fine adjustment
Cut position (or strip position) fine
adjustment
Reverse feed amount fine adjustment
Print density fine adjustment
(Thermal transfer print mode)
Print density fine adjustment
(Direct thermal print mode)
Ribbon motor drive voltage fine
adjustment (Ribbon take-up side)
Ribbon motor drive voltage fine
adjustment (Ribbon supply side)
Ribbon motor drive voltage fine
adjustment (Ribbon take-up side)
Ribbon motor drive voltage fine
adjustment (Ribbon supply side)
X-coordinate fine adjustment
5-8
Remarks
-50.0mm to +50.0mm
-50.0mm to +50.0mm
-9.9mm to +9.9mm
-20 to +20 step
-20 to +20 step
-15 to +10 step
-15 to +10 step
-15 to +10 step
-15 to +10 step
-99.5mm to +99.5mm
EO18-33031
5.4 DIAGNOSTIC

Hide quick links:

Advertisement

Table of Contents
loading