4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
4.8.4 RFID Operation Check
1.
Mount the Left Side Cover in a reverse order of removal. Be careful not to pinch the cables.
Left Side Cover
2.
Plug the Power cord into the electrical outlet and turn ON the printer. Enter the RFID Set-up Menu in the
System Mode.
Power OFF
[Turn on the printer while holding
down [FEED] & [PAUSE] or [MODE].
SYSTEM MODE
<0>RESET
<1> DIAGNOSTIC
<2> SET PARAMETERS
<3>TEST PRINT
3. In the module configuration, press the [ENTER] key to select the "UHF band (U2 / U4)".
4.
Set the country code to [EU].
Module
TYPE
COUNTRY Need to be set
Change by [ENTER] key
Press the [ENTER] Key.
Enter PASSWORD(RFID) and 1048, then save by pressing the [ENTER] key.
Confirm the COUNTRY CODE is set to [EU] and press the [ENTER] key.
5.
Turn off the printer power and back to on again. Enter the system mode.
6. Under the module setting, select [EPC C1 Gen2] as the Tag Type and press the [ENTER] key.
Press [DOWN]
until "<7>RFID" is
highlighted.
U2/U4
4.8 UHF RFID KIT (B-EX706-RFID-U4-US/EU/AU-R)
SYSTEM MODE
<5>RAM CLEAR
<6>INTERFACE
<7>RFID
<8>RTC
4-46
EO18-33031
(Revision Date: Mar. 1, 2017)
Press [ENTER].