15. MAJOR UNIT REPLACEMENT
6)
Loosen the two bottom screws of the Ribbon shaft holder plate.
7)
Remove the two platen rollers by unhooking the respective platen holders. After that, remove the 2
screws indicated in the picture below.
Platen Roller
Platen Holder
8)
By this time you can already remove the whole Paper Guide Assembly.
9)
Replace the Paper Guide Assembly with a new one, then reassemble in the reverse order of removal.
Paper Guide Assembly
15-30
EM18-33031
15.14 PAPER GUIDE ASSEMBLY