15. MAJOR UNIT REPLACEMENT

15.5 RIBBON MOTORS (TAKE-UP, FEED)

15.5.1 Ribbon Motor (Take-up)

1) Remove the side panel (L). (Refer to Section 3.2.)
2) Disconnect the relay cable from the ribbon motor (take-up).
3) Remove the two SMW-3x6 screws to detach the ribbon motor (take-up).
4) Replace the ribbon motor (take-up) with a new one, then reassemble in the reverse order of
removal.
• Fit the positioning tabs of the ribbon motor (take-up) into the positioning holes in the ribbon
motor mounting plate.
• Apply FLOIL HTM-308 to the pulley using a soft cloth.
Ribbon Motor (Take-up)
5) Refer to Section 5.5.28 to fine adjust the ribbon motor torque.
Positioning Tab
Pulley
Ribbon Motor Mounting Plate
15-9
(Revision Date: Mar., 2020)
15.5 RIBBON MOTORS (TAKE-UP, FEED)
SMW-3x6 Screw
Ribbon Motor (Take-up)
Relay Cable
Positioning Hole
EM18-33031