4. INSTALLATION PROCEDURE FOR OPTIONAL EQUIPMENT
3) Set an
AGC threshold of data write.
Set a value which is lower than the AGC value by 1 or 2, taking variation of RFID tags in performance into
consideration.
(1) Choose "UHF SETTING", and press the [ENTER] key.
(2) Choose "WRITE AGC THRESHOLD", and press the [ENTER] key.
(3) Set a threshold value with [UP] or [DOWN] key, then press the [ENTER] key.
When the measured AGC was 9, for example, set "8" (a value lower than the measured AGC by 1
or 2.)
(4) Choose "WRITE RETRY MIN AGC", and press the [ENTER] key.
(5) Set a lower limit with the [UP] or [DOWN] key.
Usually, set the same value with the AGC threshold for data write (WRITE AGC THRESHOLD).
In the case of this example, set "8" and press the [ENTER] key.
(6) AGC threshold setting is completed.
Reference: Recommended setting for RFID tag and Label (Example)
Answer date
Basic
Dealer/SI
Information
Label
Antenna Position
Kinds of sealed label
Antenna sealed sheet
Printer
Retry
setting
UHF
Application
Writing position(@0003)
setting
Remarks
B-EX6T1, Recommended setting for RFID Tag and Label
5/Sep/2016
XXXXXXXX
Manufacturer
ZZZZ
The adjustment for reprinting
The number of re print
Reading try
Writing try
Output level
Q value
Tag performance judgment
The performance threshold
for writing
The performance threshold
for writing(Lower limit)
4.8 UHF RFID KIT (B-EX706-RFID-U4-US/EU/AU-R)
End User
Label Size
F / C / R
F / C / R
Need / No need
+3mm
3
5 times 4.0s
5 times 2.0s
13
2
10
10
10
4-59
EO18-33031
(Revision Date: Mar. 1, 2017)
YYYYY
W 80mm X L 60mm Gap 5 mm
These values need to be
set in the SYSTEM mode.
RFID setting.
(Caution)
These values are different
depending on the tag
used.