Calibrate - Toshiba BA400 Series Key Operation Specification

Hide thumbs Also See for BA400 Series:
Table of Contents

Advertisement

Initial feed ... Restart
label ... Finished (*)
th
Printing: 4
label ... Finished (*)
Printing: 5
th
(*) Completely printed labels: 1
(3) Ribbon end detection: In the case unfinished label length is less than 30 mm
 Printer behavior
When a label end is detected in the middle of printing, the printer completes the half-finished printing
and stops when the next label is at the home position, displaying the error message.
* Printing of the half-finished label is completed.
 LCD message
"NO RIBBON"
 The remaining number labels
[Specified number of labels]  [The number of finished labels at the time of printing stop (including the
half-finished label)]
If a ribbon end is detected while the last one of the specified number of labels is printed, the remaining
number of labels on the LCD will be blank.
 Printer behavior at restart
When the printing is restarted, first the initial feed is performed, then the printer starts printing from the
next label. In case the label end was detected while the last one of the specified number of labels was
printed, only the initial feed is performed, and if the status response has been set to ON, an issue end
status is sent after a feed end status.
<Example>
Specified number of labels = 5, A ribbon end is detected while the 3rd label is printed. Unfinished label
length is less than 30 mm
label ... Finished (*)
st
Printing: 1
nd
Printing: 2
label ... After an error is detected, printing is completed. Finished (*)
Printing: 3
rd
Stop with error ... "NO RIBBON" is displayed on the LCD.
Initial feed ... Restart
label ... Finished (*)
th
Printing: 4
label ... Finished (*)
th
Printing: 5
(*) Completely printed labels: 1
8.5.10

CALIBRATE

OFF:
ON TRANSMISSIVE:
ON REFLECTIVE
ON ALL:
ON TRANS+BackFeed: Auto calibration is performed with transmissive sensor, then the media is fed
ON REFL+BackFeed:
ON ALL+BackFeed:
st
nd
, 2
label ... Finished (*)
st
to 5
Auto calibration is not performed.
Auto calibration is performed with transmissive sensor.
Auto calibration is performed with reflective sensor.
Auto calibration is performed with both sensors.
backward.
Auto calibration is performed with reflective sensor, then the media is fed
backward.
Auto calibration is performed with both sensors, then the media is fed backward.
th
th
, 4
and 5
labels
th
labels
78