(13) Removal of the Fusing Pressure/Retraction Motor

1. Remove the MSC/PIC Board Box.
D-41 (steps 1 through 8)
2. Remove the Fusing Drive Motor.
3. Remove two screws and the harness holder.
4004D063AA
4. Unplug two connectors.
5. Remove three screws and the Fusing Pressure/
Retraction Motor Assy.
4004D064AA
6. Snap off one E-ring and remove the gear and pin.
NOTE
• Use care not to lose the pin.
7. Snap off one E-ring and remove the bushing.
8. Remove two screws and the Fusing Retraction
Position Sensor mounting bracket.
4004D125AA
9. Remove the gear (black).
4004D209AA
10. Remove two screws and the Fusing Pressure/
Retraction Motor.
4004D126AB