(15) Removal of the Exposure Lamp

1. Remove the IR Right Cover and Original Glass.
2. Remove the Scanner Assy.
D-30

(16) Removal of the Temperature Fuse

1. Remove the IR Right Cover and Original Glass.
2. Remove the Scanner Assy.
D-30
3. Take out the Scanner Assy by turning it in the
direction of the arrow shown.
NOTE
• The Scanner Assy cannot be completely taken off
the copier as a Flat Cable is still connected to it at
this time.
4004D017AB
4. Remove two screws, unplug one connector, and
remove the Scanner Assy Flat Cable.
5. Remove the Scanner Assy.
4004D025AA
3. Remove the Exposure Lamp from the Lamp Ter-
minals.
4. Remove the Exposure Lamp.
4004D040AB
3. Remove one screw and the fuse cover.
4004D041AA
D-31