11-4.
Original Size Detection Timing
1. Original size detection : When the Original Cover is raised to an angle of 15° or
2. Original size validation : When the Original Cover is lowered to an angle of less than
3. Original size reset
Original Cover Detecting Sensor
(PC25)
Controlled Part
PC25
more (Original Cover Detecting Sensor is unblocked).
15° (Original Cover Detecting Sensor is blocked) or when
the Start key is pressed with the Original Cover Detecting
Sensor unblocked.
: When the Original Cover Detecting Sensor is unblocked as
the Original Cover is raised.
Control Signal
PWB-C PJ2C-2B
M-36
4004M512AA
Blocked
Unblocked
L
H
WIRING DIAGRAM
20-H