Cd-Mag - Minolta CF1501 Service Manual

Hide thumbs Also See for CF1501:
Table of Contents

Advertisement

(14) CD-Mag.

Requirement
200 mm
Specifications
200 ± 1.0 mm
This adjustment must be made in any of the following cases:
• The CCD Unit has been replaced.
• The lens has been replaced.
Adjustment Procedure
1. Call the Tech. Rep. Mode to the screen.
2. Touch these keys in this order: "Machine Adjust" → "IR Area."
3. Touch "CD-Mag."
4. Place a scale on the Original Glass so that it runs parallel with the Original Width Scale
and its leading edge is aligned with the Original Length Scale.
5. Press the Start key to make a copy.
6. Check the image on the copy produced.
✽ If the image does not meet the specifications:
7. Change the setting using the Up/Down key.
Adjustment Instructions
If the specified width on the copy is less than 199 mm, increase the setting.
If the specified width on the copy exceeds 201 mm, decrease the setting.
8. Press the Start key to make a copy.
9. Check the image on the copy to see if the specifications are met.
10. If it fails to meet the specifications, change the setting and make a check again.
11. If it meets the specifications, touch "MENU."
The 200-mm width of the scale on the sample copy
produced should fall within the following range.
4004D516AB
Adjustment Mode
CD-Mag.
D-84
Setting Range
0.990 to 1.010

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cf2001

Table of Contents