(29) Removal of the 1st Image Transfer Retraction Position Sensor

(30) Removal of the Double Feed Sensor

1. Remove the 1st Image Transfer Pressure/Retrac-
tion Motor.
D-43
2. Remove four screws and the 1st Image Transfer
Retraction Position Sensor Assy.
4004D133AA
3. Unplug one connector.
4. Remove the sensor fixing bracket and 1st Image
Transfer Retraction Position Sensor.
4004D134AA
1. Pressing the tabs of the right and left rails, slide
out the drawer.
4004D135AA
4004D136AA
2. Unplug one connector.
3. Remove one screw and the Double Feed Sensor.
4004D137AB